TM2361 (24JUN08) 9025-25-67 450DLC Excavator Operation and Tests 062608 PN=927 Tests Cylinder Drift Test—Arm, Boom, and Bucket Monitoring Pump 1 Delivery Pressure 0.00 MPa SPECIFICATIONS Pump 2 Delivery Pressure 0.00MPa Cylinder Drift Test—Arm, Boom, and Bucket Hydraulic Oil Temperature 0 oC Hydraulic Oil Temperature 45—55°C Actual Engine Speed --------min-1 110—130°F –19–03MAR06 Bucket Load Weight 2850 kg approximate ON 6280 lb approximate 1 2 3 4 5 Test Time 5 minutes 6 7 8 9 0 TX1003295 Boom Cylinder Drift 15 mm maximum F1 F2 F3 F4 0.6 in. maximum Arm Cylinder Drift 20 mm maximum Monitor 0.8 in. maximum Bucket Cylinder Drift 20 mm maximum 0.8 in.
maximum Bucket Bottom to Ground Drift 100 mm maximum 3.9 in. The following test is used to check the leakage past the cylinder piston seals and past the spools in the control valve. 1. SERVICE ADVISOR application. See SERVICE ADVISOR Connection Procedure for instruction. (Group 9015-20.) Access Cylinder Drift Test. Or select the following items from the menu: • Hydraulic Oil Temperature • Actual Engine Speed 2. See Personal Digital Assistant (PDA) Connection To Excavator Using Dr. ZX Application for instruction. (Group 9015-20.) Select the following items from the Monitor Display: • Hydraulic Oil Temperature • Actual Engine Speed 3.
See Monitor Service Menu Operation for instruction to actuate the service menu on monitor in cab. (Group 9015-20.) Select the following items from monitor list: • Hydraulic Oil Temperature • Actual Engine Speed SERVICE ADVISOR is a trademark of Deere & Company Continued on next page TX04577,00000F8 –19–15MAY08–1/3 9025 25 67 Hydraulic Oil Temperature Bucket Load Weight 45—55°C 110—130°F 2850 kg approximate 6280 lb approximate Test Time 5 minutes Boom Cylinder Drift 15 mm maximum 0.6 in. maximum Arm Cylinder Drift 20 mm maximum 0.8 in. maximum Bucket Cylinder Drift 20 mm maximum 0.8 in. maximum Bucket Bottom to Ground Drift 100 mm maximum 3.9 in.