John Deere 450DLC — Pump Flow Test

TM2361 (24JUN08) 9025-25-73 450DLC Excavator Operation and Tests 062608 PN=933 Tests 13. Slowly close the loading valve on flowmeter to obtain the specified pressures. Record flow rate at each pressure. Specification Pump 1 or Pump 2—Flow Rate— New.............................................................. 360.0 L/min at 13.8 MPa and 1850 rpm 360.0 L/min at 13 790 kPa and 1850 rpm 360.0 L/min at 137.9 bar and 1850 rpm 95.1 gpm at 2000 psi and 1850 rpm Pump 1 or Pump 2—Flow Rate— New..............................................................

348.6 L/min at 20.7 MPa and 1850 rpm 348.6 L/min at 20 685 kPa and 1850 rpm 348.6 L/min at 206.8 bar and 1850 rpm 92.1 gpm at 3000 psi and 1850 rpm Pump 1 or Pump 2—Flow Rate— Minimum Allowable...................................... 305.9 L/min at 13.8 MPa and 1850 rpm 305.9 L/min at 13 790 kPa and 1850 rpm 305.9 L/min at 137.9 bar and 1850 rpm 80.8 gpm at 2000 psi and 1850 rpm Pump 1 or Pump 2—Flow Rate— Minimum Allowable...................................... 294.5 L/min at 20.7 MPa and 1850 rpm 294.5 L/min at 20 685 kPa and 1850 rpm 294.5 L/min at 206.8 bar and 1850 rpm 77.8 gpm at 3000 psi and 1850 rpm 14. Open loading valve. Stop the engine.

Pump flow rate can be increased some by adjusting the pump servo piston maximum flow adjusting screw. See Pump Servo Piston Maximum Flow Test and Adjustment. (Group 9025-25.) LD30992,000028A –19–05JUN06–5/5 9025 25 73