TM2361 (24JUN08) 9025-25-74 450DLC Excavator Operation and Tests 062608 PN=934 Tests Fan Drive System Relief Valve Test and Adjustment SPECIFICATIONS adjusted to protect components from damage caused Hydraulic Oil Temperature 45—55°C by excessive pressure. 110—130°F Engine Speed Fast Idle 1. Connect one of the following test equipment to monitor hydraulic oil temperature and actual engine Work Mode Switch Position Dig Mode speed. Power Mode Switch Position HP (High Power) Mode Auto Idle Switch Position Off 1. SERVICE ADVISOR application. See Fan Drive System Relief Valve 26.2 MPa SERVICE ADVISOR Connection Procedure for Pressure 26 200 KPa instruction.
(Group 9015-20.) 262 bar Access Fan Drive System Relief Valve Test. 3800 psi. Or select the following items from the menu: Fan Drive System Relief Valve 1.7 MPa approximate per 1/4 • Hydraulic Oil Temperature Pressure Change turn 1723 kPa approximate per 1/4 • Actual Engine Speed turn 17.2 bar approximate per 1/4 2. See Personal Digital Assistant (PDA) Connection turn To Excavator Using Dr. ZX Application for 250 psi approximate per 1/4 instruction. (Group 9015-20.) turn Select the following items from the Monitor Display:
SERVICE EQUIPMENT AND TOOLS • Hydraulic Oil Temperature 4200465 (1/4 M BSPP ORB x 7/16-20 M 37°) Adapter • Actual Engine Speed JT02156A Digital Pressure/Temperature Analyzer JT02162 Transducer, 35 000 kPa (350 bar) (5000 psi) 3. See Monitor Service Menu Operation for 35 000 kPa (350 bar) (5000 psi) Gauge instruction to actuate the service menu on X12FNL-S (Parker No. 12FNL-S) (-12 F ORFS) Cap monitor in cab. (Group 9015-20.) Select the following items from Monitoring list: The purpose of fan drive system relief valve is to limit • Hydraulic Oil Temperature the maximum system pressure in the fan drive • Actual Engine Speed hydraulic system. The relief valve is checked and 9025 25 74 2.
Push the pressure release button on top of hydraulic oil tank to relieve pressure. SERVICE ADVISOR is a trademark of Deere & Company Continued on next page LD30992,0000285 –19–16MAY08–1/3 SPECIFICATIONS Hydraulic Oil Temperature 45—55°C 110—130°F Engine Speed Fast Idle Work Mode Switch Position Dig Mode Power Mode Switch Position HP (High Power) Mode Auto Idle Switch Position Off Fan Drive System Relief Valve Pressure 26.2 MPa 26 200 KPa 262 bar 3800 psi. Fan Drive System Relief Valve Pressure Change 1.7 MPa approximate per 1/4 turn 1723 kPa approximate per 1/4 turn 17.2 bar approximate per 1/4 turn 250 psi approximate per 1/4 turn