TM2361 (24JUN08) 9025-25-75 450DLC Excavator Operation and Tests 062608 PN=935 Tests 29 Y14 30 28 15 –UN–26APR06 TX1007028 27 16 TX1007028 Fan Drive Pump Test Port 15—Pump 1 27—Pilot Pump 29—Test Port Y14—Fan Pump Control 16—Pump 2 28—Fan Drive Pump 30—Delivery Line Solenoid Valve 3. Remove plug from fan drive pump test port (29). Specification Hydraulic Oil—Temperature................................................. 45—55°C 110—130°F Install the 4200465 Adapter (A). 6. Stop the engine. 4. Connect the JT02156A Digital Pressure/Temperature Analyzer and JT02162 7. Push the pressure release button on top of Transducer or a 35 000 kPa (350 bar) (5000 psi) hydraulic oil tank to relieve pressure.
gauge. See JT02156A Digital Pressure/Temperature Analyzer Installation for instruction. 5. Heat hydraulic oil to specification. See Hydraulic Oil Warm-Up Procedure. (Group 9025-25.) Continued on next page LD30992,0000285 –19–16MAY08–2/3 9025 25 75