Komatsu — TROUBLESHOOTING

TROUBLESHOOTING E-1 E-1 Engine does not start 20-404 PC130-7 (1) Trouble • Engine does not start Related information • The engine starting circuit is equipped with the start lock function of safety lock lever type. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Low charge level of battery Battery voltage Electrolyte specific gravity Min. 24 V Min. 1.26 2 Defective fuse No. 3 or 18 If the fuse is broken, the circuit probably has a grounding fault, etc. (See Cause 10.) If the fuse is not broken and the monitor panel does not light up, check the power supply circuit between the battery and fuse box, too.

3 Defective starting switch (Internal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. H15 (male) Starting switch Resistance Between (1) and (4) OFF Min. 1 Mz START Max. 1 z 4 Defective safety lock switch (Internal disconnection) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch. S14 (female) Safety lock lever Resistance Between (1) and (3) Free Min. 1 Mz Lock Max. 1 z 5 Defective starting motor cutout relay R11 or R13 (Internal disconnection or short circuit) aPrepare with starting switch OFF, then carry out troubleshooting with- out turning starting switch.

R11 (female), R12 Resistance Between (1) and (2) 100 – 500 z Between (3) and (5) Min. 1 Mz Between (3) and (6) Max. 1 z 6 Defective starting motor safety relay (Internal defect) aPrepare with starting switch OFF (Disconnect only terminal C), then turn starting switch to START position and carry out troubleshooting. Relay terminal, A27 Starting switch Voltage/Resistance Between B and chassis ground Power supply START 20 – 30 V Between E and chassis ground GND Max. 1 z Between A27 (2) and chassis ground Genera- tion signal Max.

1 V Between A27 (1) and chassis ground Starting input 20 – 30 V Between C and chassis ground Starting output 20 – 30 V If the power supply, GND, generation signal, and starting input are nor- mal and the starting output is not normal, the starting motor safety relay is defective. 7 Defective starting motor (Internal defect) aPrepare with starting switch OFF, then turn starting switch to START position and carry out troubleshooting.

Starting motor Starting switch Voltage Between B and chassis ground Power supply START 20 – 30 V Between C and chassis ground Starting output 20 – 30 V If the power supply and starting signal are normal and the starting motor does not rotate, the starting motor is defective.