TROUBLESHOOTING H-3, H-4 H-3 Work equipment, swing, and travel systems do not work H-4 Abnormal sound comes out from around hydraulic pump 20-508 PC130-7 (1) Trouble • Work equipment, swing, and travel systems do not work. Related information • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of PPC lock solenoid valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting.

Safety lock lever Solenoid valve output pressure LOCK 0 MPa {0 kg/cm2} FREE 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Malfunction of self-reduc- ing pressure valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting. Control levers Control circuit basic pressure All levers in neutral 2.84 – 3.43 MPa {29 – 35 kg/cm2} 3 Malfunction of piston pump The piston pump may have a malfunction or has an internal defect. Check it by the following method. • Remove the pump discharge pressure pickup plug and crank the en- gine. If the oil flows out at this time, the piston pump is normal. 4 Defective damper The pump shaft may not rotate because of an defect in the damper.

Check the damper directly. Trouble • Abnormal sound comes out from around hydraulic pump. Related information • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Lowering of hydraulic oil level Check it directly. 2 Defective hydraulic oil Hydraulic oil may contain air. Check hydraulic oil directly. 3 Clogging of hydraulic tank cap Negative pressure may be applied to the hydraulic tank because of clog- ging of the hydraulic tank cap. Check the cap directly.

4 Clogging of hydraulic tank strainer Negative pressure may be applied to the suction circuit because of clog- ging of the hydraulic tank strainer. Check the strainer directly. 5 Defective piston pump The piston pump may have a defect in it. Check it directly.