Komatsu — TROUBLESHOOTING

TROUBLESHOOTING H-5, H-6 H-5 Auto-decelerator does not operate H-6 Fine control performance or response is low PC130-7 20-509 (1) Trouble • Auto-decelerator does not operate. Related information • Apply this troubleshooting if the auto-decelerator does not operate when the travel lever is operated. (The shuttle valve (in the PPC valve) is installed between the PPC valve and oil pressure switch of only in the travel circuit.) • Carry out the troubleshooting in working mode A.

Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of travel PPC valve (shuttle valve) aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting. Travel lever PPC valve output pressure Neutral position 0 MPa {0 kg/cm2} Travel position 2.84 – 3.43 MPa {29 – 35 kg/cm2} Trouble • Fine control performance or response is low. Related information • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Clogging of LS circuit orifice The LS circuit may be clogged.

Check it directly. 2 Defective adjustment or malfunction LS valve aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting. Measured oil pressure Oil pressure ratio All levers in neutral Either track shoe driven idle (Full stroke) Pump discharge pressure Almost same pressure 1 LS valve output pressure 0.6 (3/5) If the oil pressure does not become normal after adjustment, the LS valve may have a malfunction or a defect in it. Check the LS valve directly. 3 Defective servo piston The servo piston may have a malfunction. Check it directly.