TROUBLESHOOTING H-8 H-8 Speed or power of arm is low PC130-7 20-511 (1) Trouble • Speed or power of arm is low. Related information • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of left PPC valve (boom circuit) aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting. Left work equipment control lever PPC valve output pressure Neutral position 0 MPa {0 kg/cm2} Arm IN position Arm OUT position 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Malfunction of arm control valve (spool) The spool of the arm control valve may have a malfunction.
Check it directly. 3 Malfunction of arm control valve (pressure compensa- tion valve) The pressure compensation valve of the arm control valve may have a malfunction. Check it directly. 4 Malfunction or defective seal of arm control valve (suction valve) The suction valve of the arm control valve may have a malfunction or a defective seal. Check it directly. 5 Malfunction or defective seal of centralized safety- suction valve The centralized safety-suction valve may have a malfunction or a defec- tive seal. Check it directly.
(A trouble of the centralized safety-suction valve have bad effects on the boom and bucket.) 6 Malfunction of arm cylinder (cylinder unit) aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting. Arm cylinder Leakage from cylinder Relieved in IN position 15 cc/min