Komatsu — TROUBLESHOOTING

TROUBLESHOOTING H-9 H-9 Speed or power of bucket is low 20-512 PC130-7 (1) Trouble • Speed or power of bucket is low. Related information • Carry out the troubleshooting in working mode A. Possible causes and standard value in normal state Cause Standard value in normal state/Remarks on troubleshooting 1 Malfunction of right PPC valve (bucket circuit) aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting.

Right work equipment control lever PPC valve output pressure Neutral position 0 MPa {0 kg/cm2} Bucket CURL position Bucket DUMP position 2.84 – 3.43 MPa {29 – 35 kg/cm2} 2 Malfunction of bucket con- trol valve (spool) The spool of the bucket control valve may have a malfunction. Check it directly. 3 Malfunction of bucket con- trol valve (pressure com- pensation valve) The pressure compensation valve of the bucket control valve may have a malfunction. Check it directly. 4 Malfunction or defective seal of bucket control valve (suction valve) The suction valve of the bucket control valve may have a malfunction or a defective seal. Check it directly.

5 Malfunction or defective seal of centralized safety- suction valve The centralized safety-suction valve may have a malfunction or a defec- tive seal. Check it directly. (A trouble of the centralized safety-suction valve have bad effects on the boom and arm.) 6 Malfunction of bucket cylin- der (cylinder unit) aPrepare with engine stopped, then run engine at high idling and carry out troubleshooting. Bucket cylinder Leakage from cylinder Relieved in CURL position 15 cc/min