TESTING AND ADJUSTING TESTING AND ADJUSTING OIL PRESSURE IN WORK EQUIPMENT, SWING, AND TRAVEL CIRCUITS 6) After finishing adjustment, check again that the pressure is normal according to the above described measurement procedure. a If the high pressure setting side is adjusted, the low pressure setting side changes. Accordingly, adjust the low pressure setting side, too. 3. Adjusting swing relief pressure a If the relief pressure of the swing circuit is abnormal, adjust swing motor safety valve (8) according to the following procedure. 2.
Adjusting main relief pressure (Low pressure setting side) a If the low relief pressure of the work equip- ment circuit is abnormal or the high pressure setting was adjusted, adjust the low pressure setting side of main relief valve (2) according to the following procedure. a The low relief pressure is the pressure applied when the 2-stage relief solenoid valve is turned OFF and the pilot pressure is not applied to the selector port. 1) Disconnect pilot hose (3). 2) Fixing holder (6), loosen locknut (7). 3) Turn holder (6) to adjust the pressure. a If the holder is turned to the right, the pressure rises. turned to the left, the pressure low- ers. a Quantity of adjustment per turn of holder:
Approx. 12.6 MPa {Approx. 128 kg/cm 2 } 4) Fixing holder (6), tighten locknut (7). 3 Locknut: 53.9 – 63.7 Nm {5.5 – 6.5 kgm} 1) Fixing adjustment screw (9), loosen locknut (10). 2) Turn adjustment screw (9) to adjust the pres- sure. a If the adjustment screw is turned to the right, the pressure rises. turned to the left, the pressure low- ers. a Quantity of adjustment per turn of adjust- ment screw: Approx. 14 MPa {Approx. 143 kg/cm 2 } 3) Fixing adjustment screw (9), tighten locknut (10). 3 Locknut: 53.9 – 73.5 Nm {5.5 – 7.5 kgm} 5) Connect pilot hose (3). 6) After finishing adjustment, check again that the pressure is normal according to the above described measurement procedure.
4) After finishing adjustment, check again that the pressure is normal according to the above described measurement procedure. 20-124 PC130-7 (1)