Komatsu — 20-201--.pdf

TESTING AND ADJUSTING MEASURING CONTROL CIRCUIT BASIC PRESSURE MEASURING CONTROL CIRCUIT BASIC PRESSURE 4. Run the engine at high idling and set all the con- trol levers in neutral and measure the oil pres- sure. a Measuring instruments for control circuit basic pressure k Lower the work equipment to the ground and stop the engine. Operate the control levers several times to release the residual pressure in the piping, and then loosen the oil filler cap of the hydraulic tank slowly to release the internal pressure of the hydraulic tank. 5. After finishing measurement, remove the mea- suring instruments and return the removed parts. 1.

Open the pump room cover and remove control circuit basic pressure pickup plug (1) under the hydraulic pump. a Do not adjust the relief valve for the control cir- cuit basic pressure is not adjustable. 2. Install nipple J2 and connect it to oil pressure gauge [1] of hydraulic tester J1 . a Use the oil pressure gauges of 5.9 MPa {60 kg/cm 2 }. 3. Run the engine and heighten the hydraulic oil temperature to 45 – 55°C. PC130-7 20-125 (1) Symbol Part No. Part name J 1 799-101-5002 Hydraulic tester 790-261-1203 Digital hydraulic tester 2 799-101-5230 Nipple (10 x 1.25 mm) 07002-11423 O-ring