TESTING AND ADJUSTING TESTING AND ADJUSTING OIL PRESSURE IN PUMP PC CONTROL CIRCUIT TESTING AND ADJUSTING OIL PRESSURE IN PUMP PC CONTROL CIRCUIT (2): PC valve output pressure pickup plug (at top of hydraulic pump) a Testing and adjusting instruments for oil pressure in pump PC control circuit MEASURING Measuring PC valve output pressure (servo pis- ton inlet pressure) a Before measuring the PC valve output pressure (servo piston inlet pressure), check that the oil pressure in the work equipment, swing, and travel circuits and the basic pressure in the con- trol circuit are normal.
a Measure the PC valve output pressure (servo piston inlet pressure) and pump discharge pres- sure simultaneously and compare them. 3. Install nipple K2 and connect it to oil pressure gauge [1] of hydraulic tester K1 . a Use the oil pressure gauge of 58.8 MPa {600 kg/cm 2 }. The drawing shows the pump discharge pressure side. k Lower the work equipment to the ground and stop the engine. Operate the control levers several times to release the residual pressure in the piping, and then loosen the oil filler cap of the hydraulic tank slowly to release the internal pressure of the hydraulic tank. 1. Remove the top cover of the control valve and open the pump room cover. 2.
Remove oil pressure pickup plugs (1) and (2). (1): Pump discharge pressure pickup plug (at top of control valve) The drawing shows the PC valve output pressure side. 4. Run the engine and heighten the hydraulic oil temperature to 45 – 55°C. 20-126 PC130-7 (1) Symbol Part No. Part name K 1 799-101-5002 Hydraulic tester 790-261-1203 Digital hydraulic tester 2 799-101-5220 Nipple (10 x 1.25 mm) 07002-11023 O-ring