TESTING AND ADJUSTING MEASURING PPC VALVE OUTPUT PRESSURE MEASURING PPC VALVE OUTPUT PRESSURE a Measuring instruments for PPC valve output pressure a Before measuring the PPC valve output pres- sure, check that the basic pressure in the control circuit is normal. k Lower the work equipment to the ground and stop the engine. Operate the control levers several times to release the residual pressure in the piping, and then loosen the oil filler cap of the hydraulic tank slowly to release the internal pressure of the hydraulic tank. a Since PPC oil pressure switches (10) and (11) are installed in the battery room, open the battery room cover. 1.
Disconnect PPC oil pressure switches (1) – (4) of the circuit to be measured. 2. Install nipple [1] of hydraulic tester N and con- nect it to oil pressure gauge [2]. a Use the oil pressure gauges of 5.9 MPa {60 kg/cm 2 }. a The figure shows the measuring instruments installed to the mounting part of the swing LEFT PPC pressure switch. a Since PPC oil pressure switches (1) – (8) are installed in the battery room, open the bat- tery room cover. a Since PPC oil pressure switch (9) is installed on the under side of the floor frame, remove the cab undercover (on the front side). 3. Run the engine and heighten the hydraulic oil temperature to 45 – 55°C. PC130-7 20-135 (1) Symbol Part No.
Part name N 799-101-5002 Hydraulic tester 790-261-1203 Digital hydraulic tester No. Circuit to be measured No. Circuit to be measured 1 Boom RAISE (S06) 7 Swing RIGHT (S07) 2 Boom LOWER (S02) 8 Swing LEFT (S03) 3 Arm IN (S04) 9 Travel (S30) 4 Arm OUT (S04) 10 1ATT on front side (S10) 5 Bucket CURL (S08) 11 1ATT on rear side (S11) 6 Bucket DUMP (S01)