TESTING AND ADJUSTING MEASURING OIL LEAKAGE MEASURING OIL LEAKAGE 2. Measuring oil leakage from arm cylinder 1) Run the engine and raise the engine oil tem- perature to 45 – 55°C, and then move the arm cylinder to the IN stroke end. a Measuring instruments fro oil leakage k Release the residual pressure in the piping on the arm cylinder head side. For details, see RELEASING RESID- UAL PRESSURE IN HYDRAULIC CIR- CUIT (Operate the lever in the arm IN direction only, however). 2) Disconnect hose (2) on the cylinder head side and block the hose side with a plate. 1.
Measuring oil leakage from boom cylinder 1) Run the engine and heighten the engine oil temperature to 45 – 55°C, and then move the boom cylinder to the RAISE stroke end. k Release the residual pressure in the piping on the boom cylinder head side. For details, see RELEASING RESID- UAL PRESSURE IN HYDRAULIC CIR- CUIT (Operate the lever in the boom RAISE direction only, however). 2) Disconnect hose (1) on the cylinder head side and block the hose side with a plate. k Take care not to disconnect the hose on the cylinder bottom side. a Use the following part to block the hose side. 07376-50522 (Plug No. 05) k Take care not to disconnect the hose on the cylinder bottom side.
a Use the following part to block the hose side. 07376-50422 (Plug No. 04) 3) Run the engine at high idling and relieve the arm circuit by moving the arm IN. k Take care not to "move the arm OUT". 4) Measure the oil leakage for 1 minute after 30 seconds since relieving is started. 5) After finishing measurement, return the removed parts. 3) Run the engine at high idling and relieve the boom circuit by raising the boom. k Take care not to "lower the boom". 4) Measure the oil leakage for 1 minute after 30 seconds since relieving is started. 5) After finishing measurement, return the removed parts. PC130-7 20-139 (1) Symbol Part No. Part name P Commercially available Measuring cylinder