TESTING AND ADJUSTING RELEASING RESIDUAL PRESSURE IN HYDRAULIC CIRCUIT RELEASING RESIDUAL PRESSURE IN HYDRAULIC CIRCUIT 4) Repeat steps 2) and 3) above 2 – 3 times, and the residual pressure in the piping is released completely. 1. Releasing residual pressure in hydraulic tank k Since the hydraulic tank is enclosed and pressurized, release the residual pressure in it when removing a hose or a plug con- nected to it. 1) Lower the work equipment to the ground in a stable position and stop the engine. 2) Loosen oil filler cap (1) of the hydraulic tank gradually to release the air in the tank.
a If you open the pump room cover, you can loosen the oil filler cap from the right side of the machine. 3. Releasing residual pressure in swing motor circuit a The residual pressure in the swing motor cir- cuit can be released by performing the oper- ation for RELEASING RESIDUAL PRESSURE IN HYDRAULIC CYLINDER CIRCUIT (Operate the lever in the swing direction only, however). 4. Releasing residual pressure in travel motor circuit a Since the control valve spool of the travel motor circuit is open, the pressure in this cir- cuit can be released by performing RELEAS- ING RESIDUAL PRESSURE IN HYDRAULIC TANK. 2.
Releasing residual pressure in hydraulic cyl- inder circuit k When disconnecting a pipe between a hydraulic cylinder and the control valve, release the residual pressure in the piping according to the following procedure. 1) Release the residual pressure in the hydrau- lic tank. For details, see RELEASING RESIDUAL PRESSURE IN HYDRAULIC TANK. a Keep the oil filler cap of the hydraulic tank removed. 2) Turn the starting switch ON and set the safety lock lever in the FREE position, and then operate the work equipment control levers on both sides forward, backward, to the right, and to the left. a The control valve is operated by the pressure in the accumulator.
The pres- sure in the accumulator is used up, how- ever, after the control valve is operated 2 – 3 times. 3) Run the engine at low idling for 10 seconds to heighten the pressure in the accumulator. 20-142 PC130-7 (1)