54 REGULAR CHECKS AND MAINTENANCE WORK 4. A boost charge is only for emergencies. It will partially charge the battery at a high rate and in a short time. When using a boost-charged battery, it is necessary to recharge the battery as early as possible. Failure to do this will shorten the battery’s service life. 5. When the specifi c gravity of electrolyte falls between 1.27 and 1.29 charge has completed. 6. When exchanging an old battery for a new one, use a battery of equal specifi cation. EVERY 50 SERVICE HOURS Battery Charging 3 CAUTION To avoid personal injury: When the battery is being activated, hydrogen and oxygen gases in the battery are extremely explosive.
Keep open sparks and fl ames away from the battery at all times, especially when charging the battery. When charging battery, remove battery vent plugs. When disconnecting the cable from the battery, start with the negative terminal fi rst. When connecting the cable to the battery, start with the positive terminal fi rst. Do not check battery charge by placing a metal object across the terminals. Use a voltmeter or hydrometer. Greasing of Swing Bearing Teeth 1. Pump greace with the grease gun through the grease nipple. 2. Grease at each 90є (1.58 rad.) position of the swing frame. 3. Fill with approx. 50g of grease (approx. 20 pumps with the grease gun). Distribute the grease over the teeth. 1.
Make sure each electrolyte level is to the bottom of vent wells, if necessary add distilled water in a well-ventilated area. 2. The water in the electrolyte evaporates during recharging. Liquid shortage damages the battery. Excessive liquid spills over and damages the excavator body. 3. To slow charge the battery, connect the battery positive terminal to the charge positive terminal and the negative to the negative, then recharge in the standard fashion. (1) Grease nipple (for Bearing teeth)