63 Hydraulic Oil Check with Hydraulic Breakers The hydraulic oil change after 1000 operating hours in the operator's manual is based on normal excavator work. Following inspection measures are valid when hydraulic breakers are used: 1. Changing and fi lling up of hydraulic oil 1) The hydraulic oil must be changed more often when breakers are used because the machine is subject to harder conditions than at normal excavating work. 2) Use only the recommended oils mentioned in the operator's manual when changing or fi ll oil. 3) When fi lling up oil, do not mix oils of different makes. 2.
Changing the return fi lter and oil 1) The fi lter must be changed more often because of contamination resulting from the frequent assembly and disassembly of the hoses. 2) Use the correct replacement fi lter. 3) Oil change according to operating hours. EVERY 1000 SERVICE HOURS OR ONCE A YEAR Replacing Air Filter Element Open the engine bonnet and remove the dust-cover. Remove and replace the outer element and inner element with new elements. When reassembling, install the dust-cover so that its TOP mark (arrow) faces up-wards. (1) Outer element (2) Inner element (3) Dust-cover (4) Clamps IMPORTANT: Shorten the replacement period if the machine is used in dusty or sandy areas.
EVERY 2000 SERVICE HOURS Do all 50, 200, 250, 500 and 1000 hour servicing at the same time. Chang Front Idler and Track Roller Oil NOTE: Contact your KUBOTA dealer for details. Check the Dynamo and Starter Motor NOTE: Contact your KUBOTA dealer for details. Hydraulic oil Return Filter Normal excavator work every 1000 Hrs. every 500 Hrs. (250Hrs. after first operation) Breaker work portion 20% every 800 Hrs. every 200 Hrs. 40% every 400 Hrs. 60% every 300 Hrs. every 100 Hrs. more every 200 Hrs.