Kubota — Changing Radiator Coolant

64 ANNUAL SERVICING Changing Radiator Coolant (In case of long-life coolant fl uid) Stop the engine then remove the key and wait until it has cooled down completely. 1. Open the drain plug on the bottom of the radiator and drain coolant completely. 2. To clean, rinse the radiator with water. 3. Close the drain plug and fi ll the radiator and the reserve tank with coolant fl uid. Let the engine idle for about 5 min., stop the engine and remove the key then check the coolant level. 4. The machine has been shipped fi lled with 50% anti-freeze solution. Electrical Wiring and Fuses Check the terminals periodically for proper connections.

Loose wiring or damaged cables can cause improper functioning or short circuiting of the electrical system. Check wiring and replace damaged components immediately. If a fuse blows out soon after having been replaced, contact your nearest KUBOTA dealer. Never use a fuse other than specifi ed. BIENNIAL SERVICING 3 CAUTION To avoid personal injury: Do not loosen the radiator cap before the radiator has cooled down suffi ciently. Then only loosen the cap and allow enough time for the pressure in the system to be released. Now remove the cap completely. Replacement of Radiator Hoses Replace radiator hoses and hose clamps ever two years.

If the hoses are swollen, hard or cracked, they must be replaced earlier. (1) Drain plug (1) Radiator cap (1) Radiator hoses (2) Hose clamps (1) Reserve tank (A) “FULL” (B) “LOW”