eng — METHOD OF OPERATING AUTO-GREASING SYSTEM

. ATTACHMENTS, OPTIONS HANDLING AUTO-GREASING SYSTEM INITIAL SETTING OF AUTO-GREASING SYSTEM 2. Adjust the pressure of air regulator valve (3) to 0.39 MPa (4 kgf/cm 2 , 56.8 PSI). 3. Close top cover (1) of the timer box. METHOD OF OPERATING AUTO-GREASING SYSTEM With this system, when the machine starting switch is turned ON, greasing starts automatically according to the interval set by the timer. 6 - 47 NOTICE er plate. Use a suitable follow If the follower plate i s not suitable, the grease pump will be u nable to feed the grease even when there is g rease remaining in the grease can. er of damage caused by insufficient greasing of the machine.

This brings the dang er of damage caused by insufficient gre asing of the 1. Open top cove r (1) of the timer box, then set grea sing interval adjustment sc rew (2) to 5 minutes. When starting to u se the auto-greasing s ystem, greas e is not supplied sufficiently to the chargi ng portion, so set the timer to a shorter t ime. After 2-3 days, th e grease will f ill the charging p ortion, so set the timer t o 20 minutes. Adjust the timer setting a ccording to the grease condition. When manual l position, greasi the switch is tur ube switch (1) on the d ng will start regardless ashboard is s of the timer s et to the ON etting. When ned OFF, greasing wi ll stop.

REMARK With the manual l ube switch, it is possible to carry out greasing regardless of the the action of the greasing. timer. This can be us ed mainly wh en checking grease pump or when carrying out additional