9. Cooling water system 9.5 Pressure cap and coolant recovery tank 9.5.1 Pressure cap construction The pressure cap mounted on the filler neck incorporates a pressure control valve. The cap is mounted on the filler neck cam by placing it on the rocking tab and rotating. The top seal of the cap seals the top of the filler neck, and the pressure valve seals the lock seat. 9.5.2 Pressure cap pressure control The pressure valve and the vacuum valve seal both the valve seats, when the pressure in the fresh water system is within the specified value of 88 kPa (0.9 kgf/ cm 2 ). This seals the fresh water system.
When the pressure within the fresh water system exceeds the specified value, the pressure valve opens, and steam is discharged through the overflow pipe. When the fresh water is cooled and the pressure within the fresh water system drops below the normal value, atmospheric pressure opens the vacuum valve, and air is drawn in through the overflow pipe. The coolant recovery tank (which sill be described later), keeps the water level from dropping due to discharge of steam when the pressure valve opens. Action of pressure control valve 9.5.3 Pressure cap inspection Refer to 2.2.6(4).
166 Pressure cap Pressure valve spring Filler neck Overflow pipe Fresh water cooler Copper tube Pressure valve Open at 82-109 kPa (0.84-1.11 kgf/cm2, 0.82-1.09 bar) Vacuum valve Open at 8 kPa (0.08 kgf/cm2) or below