SEN02303-00 30 Testing and adjusting q (9): Accessory valve 4] After finishing adjustment, check again that the oil pressure is normal according to the above described measurement procedure. a If the high pressure setting side is adjusted, the low pressure setting side changes. Accordingly, adjust the low pressure setting side, too. a Adjusting relief pressure (Low pressure setting side) q The solenoid selector valve drives actuators of 3 kinds.
a Adjusting relief pressure (High pressure setting side) q Primary conveyor motor q Conveyor elevator cylinder q The high relief pressure is the pressure applied when the 2-stage relief valve is turned OFF and the pilot pressure is not applied to the selector port. 1] Disconnect 2-stage selector pilot hose (14). q Lock cylinder (Extension and retrac- tion) q The low relief pressure is the pressure applied when the 2-stage relief valve is turned ON and the pilot pressure is applied to the selector port. 1] Disconnect 2-stage selector pilot hose (14). 2] While fixing holder (15), loosen lock- nut (16). a If the holder is q turned to the right, the pres- sure rises.
q turned to the left, the pres- sure lowers. a Quantity of adjustment per turn of holder: Approx. 25.3 MPa {258 kg/cm 2 } 2] While fixing holder (17), loosen lock- nut (18). a If the holder is q turned to the right, the pres- sure rises. 3 Locknut: 93 – 123 Nm {9.5 – 12.5 kgm} q turned to the left, the pres- sure lowers. a Quantity of adjustment per turn of holder: Approx. 25.3 MPa {258 kg/cm 2 } 3 Locknut: 78 – 93 Nm {8 – 9.5 kgm} 3] Connect pilot hose (14). 28 BR380JG-1E0