Kaiyi BR380JG-1E0 — MEASURING AND ADJUSTING OIL PRESSURE IN PUMP PC CONTROL CIRCUIT

SEN02303-00 30 Testing and adjusting a Measuring condition and method of judgment: If the output pressures are in the following range, the PC-EPC valve is normal. 1. Loosen locknut (8). a Before loosening the locknut, make counter mark at the adjustment screw end so that you can see the position of the locknut before the adjustment (and you can return the locknut to its original posi- tion after turning it in reverse). 2. Turn adjustment screw (9) clockwise or coun- terclockwise to adjust.

a Turn the adjustment screw q Clockwise when the work equipment speed is low (to increase pump absorption torque) and 5) After finishing measurement, remove the measuring tools and return the removed parts. q Counterclockwise when the engine speed lowers (to decrease pump absorption torque). Adjusting Adjusting pump PC valve a If either of the following phenomena occurs and the PC valve seems to be defective, adjust PC valves (6) and (7) according to the proce- dure shown below. 3. Tighten locknut (8). 3 Locknut: 27.5 – 34.3 Nm {2.8 – 3.5 kgm} q As the working load increases, the engine speed lowers remarkably. q The engine speed is normal but the work equipment speed is low. q (6):

Front pump PC valve q (7): Rear pump PC valve 4. After finishing adjustment, check again that the PC valve output pressure (servo piston inlet pressure) is normal according to the above described measurement procedure. 32 BR380JG-1E0 Engine All work equipment switches Output pressure Low idle OFF Approx. 2.9 MPa {Approx. 30 kg/cm2} High idle 0 MPa {0 kg/cm2}