SEN02303-00 30 Testing and adjusting 3. Measuring LS-EPC valve output pressure 1) Remove oil pressure pickup plug (5). Adjusting Adjusting LS valve a If the LS differential pressure is abnormal, adjust the LS valve according to the following procedure. q (6): Front pump LS valve q (7): Rear pump LS valve 2) Install nipple M2 and connect it to oil pres- sure gauge of hydraulic tester M1 . a Use the oil pressure gauges of 5.9 MPa {60 kg/cm 2 }. 1. While fixing adjustment screw (9), loosen lock- nut (8). 2. Turn adjustment screw (9) to adjust the differ- ential pressure. a If the adjustment screw is q Turned to the right, the differential pressure is increased.
q Turned to the left, the differential pressure is decreased. a Quantity of adjustment (LS differential pressure) per turn of adjustment screw: Approx. 1.3 MPa {Approx. 13.3 kg/cm 2 } 3) Start the engine. 4) Run the engine at high idle, Turn OFF all the work equipment switches, and mea- sure the output pressure. a Measuring condition and method of judgment: If the output pressures are in the following range, the LS-EPC valve is normal. 3. While fixing adjustment screw (9), tighten lock- nut (8). 3 Locknut: 49 – 68.6 Nm {5 – 7 kgm} All work equipment switches Output pressure 5) After finishing measurement, remove the measuring tools and return the removed parts. 4.
After finishing adjustment, check again that the LS differential pressure is normal according to the above described measurement procedure. 36 BR380JG-1E0 OFF Approx. 2.9 MPa {Approx. 30 kg/cm2}