Kaiyi BR380JG-1E0 — SPECIAL FUNCTIONS OF MACHINE MONITOR

30 Testing and adjusting SEN02304-00 27. Function of cylinder cut out operation [08] The operator can perform the engine on cylin- der cut out operation with the machine monitor. “Cylinder cut out” operation means to run the engine with 1 or more fuel injectors disabled electrically to reduce the number of effective cylinders. This operation is used to find out a cylinder which does not output power normally (combustion in it is abnormal). 1) Selecting menu Select “08 Cylinder cut out” menu from the Service Menu initial screen and press [ ] switch.

3) Resetting cut out cylinder Press the switch corresponding to the cut out cylinder number from switches [1] to [6] of the machine monitor to be reset. a If pressing the switch changes the cylinder number on the screen to a black letter enclosed in the black frame, the cylinder is reset. 2) Selecting cylinder to be cut out Press a switch corresponding to the cylin- der No. to be cut out from switches [1] to [6] of the machine monitor. a If pressing the switch changes the cylinder number on the screen to a white letter enclosed in the white frame, the cylinder is cut out (when a wrong number is selected, press the correct switch again). a Number of cylinders to be reduced is any.

BR380JG-1E0 29