Kaiyi BR380JG-1E0 — FAILURE CODE [7RF2KB] SHORT CIRCUIT IN CRUSHER FORWARD EPC VALVE

40 Troubleshooting SEN02090-00 Failure code [7RF2KB] Short circuit in crusher forward EPC valve 1 Circuit diagram related to crusher forward EPC solenoid BR380JG-1E0 41 User code Failure code Trouble Short circuit in crusher forward EPC valve (Work equipment and pump controller (work equipment control) system) — 7RF2KB Contents o trouble f • Ground short circuit is detected when EPC valve solenoid for crusher forward rotation is driven. Action of controller • Turns the output to the crusher forward EPC valve solenoid circuit OFF. • Even if the cause of the failure disappears, the system does not reset itself until the engine starting switch is turned OFF.

Problem tha appears on machine t • The crusher does not rotate forward. • When this trouble is detected, the horn sounds (3 times intermittently). Related information • The drive current of the valve solenoid for crusher forward rotation can be checked with the monitor- ing function. (Code: 25900, Crusher FWD EPC Curr.) • Since the controller detects short circuit while the solenoid output is turned ON, be sure to turn the solenoid output ON when checking for reproduction of the failure after repair. • The failure history is recorded.

Possible causes and standard val in normal sta Cause Defective crusher forward EPC valve 1 solenoid (Grounding fault) Short circuit with chas- sis ground in wiring ue 2 harness (Contact with te ground) Defective work equip- 3 ment and pump con- troller Standard value in normal state/Remarks on troubleshooting aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. V02 (male) Resistance Between (1) and (2) 7 – 14 z Between (2) and chassis ground Min. 1 Mz aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON.

Between wiring harness between C03 (female) (26) – A01 – V02 (female) (2) and chassis ground Resistance Min. 1 Mz aPrepare with engine starting switch OFF, then carry out troubleshooting without turning starting switch ON. C03 (female) Resistance Between (26) and (13), (23) 7 – 14 z Between (26) and chassis ground Min. 1 Mz