Kaiyi BR380JG-1E0 — FAILURE CODE [7RFBKZ] DISCONNECTION OR SHORT CIRCUIT IN MUCK CONVEYOR SOLENOID

40 Troubleshooting SEN02091-00 Failure code [7RFBKZ] Disconnection or short circuit in muck conveyor solenoid 1 Related electrical circuit diagram BR380JG-1E0 9 User code Failure code Trouble Disconnection or short circuit in muck conveyor solenoid (Work equipment and pump controller (work equipment control) system) — 7RFBKZ Contents of trouble • When the muck discharge conveyor solenoid was not driven, disconnection or hot short (contact with 24 V circuit) was detected. Action of controller • Turns OFF the output to the muck discharge conveyor solenoid. • Even if cause of failure disappears, system does not reset itself until engine starting switch is turned OFF.

Problem tha appears on machine t • The muck discharge conveyor does not work or does not stop. (If it does not stop, press the engine stop switch or turn OFF the engine starting switch OFF.) • Horn sounds (three intermittent sounding) upon detecting a failure. Related information • The drive state (ON/OFF) of the muck conveyor solenoid can be checked with the monitoring func- tion (Code: 25500, Solenoid Valve) • The failure history is recorded.

Possible causes and standard valu in normal sta Cause Defective muck dis- charge conveyor sole- 1 noid (Internal disconnection) Disconnection in wiring harness (Open circuit 2 or poor connector con- tact) e te Hot short in wiring har- 3 ness (Contact with 24V circuit) Defective work equip- 4 ment and pump controller Standard value in normal state/Remarks on troubleshooting ective muck dis- rge conveyor sole- (Internal onnection) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON.

AV3 (male) Resistance Between (1) and (2) 20 – 60 z connection in wiring ness (Open circuit oor connector con- ) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between C03 (female) (18) – A02 – AV3 (female) (2) Resistance Max. 1 z Wiring harness between AV3 (female) (1) – chas- sis ground Resistance Max. 1 z short in wiring har- s (Contact with 24V uit) aPrepare with engine starting switch OFF, then turn engine starting switch ON and carry out troubleshooting. Wiring harness between C03 (female) (18) – A02 – AV3 (female) (2) and chassis ground Voltage Max.

1 V ective work equip- nt and pump troller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. C03 (female) Muck discharge conveyor Voltage Between (18) and chassis ground Holds in position. Max. 1 V Operating 20 – 30 V