Kaiyi BR380JG-1E0 — FAILURE CODE [CA271] SHORT CIRCUIT IN FUEL PUMP ACTUATOR

40 Troubleshooting SEN02092-00 Failure code [CA271] Short circuit in fuel pump actuator 1 Circuit diagram related to supply pump actuator (metering unit) BR380JG-1E0 39 User code Failure code Trouble Short circuit in fuel pump actuator (Engine controller system) E10 CA271 Contents of • trouble Short circuit was detected in drive circuit of supply pump actuator. Action of • controller None in particular. Problem that • appears on • machine • Engine speed does not rise from low idle. Engine output lowers. Common rail fuel pressure rises above command value. Related • information Method of reproducing failure code: Turn starting switch ON.

1 2 Possible causes and standard value 3 in normal state 4 5 Cause Standard value in normal state/Remarks on troubleshooting Defective supply pump actuator aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. CP3 PUMP REGULATOR (male) Resistance Between (1) – chassis ground Min. 100 kz Ground fault in wiring harness (Short circuit with GND circuit) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between CE01 (female) (2) – CP3 PUMP REGULATOR (female) (1) Resistance Min.

100 kz Short circuit in wiring harness (with another wiring harness) aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. Wiring harness between CE01 (female) (2) – each of CE01 (female) pins (With all wiring har- ness connectors disconnected) Resistance Min. 100 kz Defective wiring har- ness connector Connecting parts between supply pump actuator – engine wiring harness – engine controller may be defective. Check them directly.

• Looseness of connector, breakage of lock, or breakage of seal • Corrosion, bend, breakage, push-in, or expansion of pin • Moisture or dirt in connector or defective insulation Defective engine controller aPrepare with engine starting switch OFF, then carry out troubleshooting without turning engine starting switch ON. CE01 (male) Resistance Between (2) – chassis ground Min. 100 kz