SEN02738-00 50 Disassembly and assembly 3) Using a pipe, install clevis (1) and washer (3). a Protect the pipe contact parts with cloths. 2 Fitting part: Same oil as currently applied one, grease, etc. (Apply thinly) 2 Threaded part: Anti-seizure compound (Molybdenum spray, etc.) a Tighten the flange slowly so that it will not be seized or will not catch some- thing. a Retighten the clevis by using a ham- mer. 3 Clevis: 706 – 784 Nm {72 – 80 kgm} 4) Tighten the lock screw of clevis (1) and flange (2). 3 Screw: 59 Nm {6 kgm} a Do not reuse the used lock screw. a If the lock screw hole is deviated by retightening, make a new lock screw hole. 14 BR380JG-1E0