402 Having set this mode it is still possible to get a line feed through to the printer by use of the VDU1 (send next character to printer only) statement. The character following VDU1 is not checked, thus to send a line feed one would use VDU1,10 *FX6 should always be executed after the printer type has been set by *FX5 . *FX6,0 provides no character filtering. Note that the default is that line feed characters are filtered out. *FX7 is used to select the baud rate to be used when receiving data on the RS423 interface, as follows:
*FX7,1 75 baud receive *FX7,2 150 baud receive *FX7,3 300 baud receive *FX7,4 1200 baud receive *FX7,5 2400 baud receive *FX7,6 4800 baud receive *FX7,7 9600 baud receive *FX7,8 19200 baud receive (this rate is not guaranteed) *FX8 is used to select the transmit rate to be used on the RS423 interface. *FX8,1 75 baud transmit *FX8,2 150 baud transmit *FX8,3 300 baud transmit *FX8,4 1200 baud transmit *FX8,5 2400 baud transmit *FX8,6 4800 baud transmit *FX8,7 9600 baud transmit *FX8,8 19200 baud transmit (this rate is not guaranteed) Note: The standard receive/transmit format adopted for RS423 is one start bit, eight bits, one stop bit.