410 OSBYTE call with A=&6 (6) Select character to be ignored by printer On entry, X contains the decimal ASCII code of the character to be ignored. The effect of this call can be suppressed through the use of an appropriate VDU1 statement. The default setting is X=10 (line feed). On exit, A is preserved, X contains the previous *FX6 setting, Y and C are undefined. OSBYTE call with A=&7 (7) Set RS423 receive baud rate On entry, the value in X determines the baud receive rate, as follows:

X=1 75 baud X=2 150 baud X=3 300 baud X=4 1200 baud X=5 2400 baud X=6 4800 baud X=7 9600 baud X=8 19200 baud (this rate not guaranteed) On exit A is preserved, X and Y contain the old serial ULA register contents, C is undefined. OSBYTE call with A=&8 (8) Set RS423 transmit baud rate On entry, the value in X determines the baud transmit rate, as follows: X=1 75 baud X=2 150 baud X=3 300 baud X=4 1200 baud X=5 2400 baud X=6 4800 baud X=7 9600 baud X=8 19200 baud (this rate not guaranteed) On exit A is preserved, X and Y contain the old serial ULA register contents, C is undefined.

OSBYTE call with A=&9 (9) Set flash rate of flashing colours (first colour) On entry, the value in X determines the duration in centiseconds of the first named colour, X=0 sets the duration to infinity; X=25 is the default setting. On exit, A is preserved, X and Y contain the value of the previous duration setting, C is undefined. OSBYTE call with A=&A (10) Set flash rate of flashing colours (second colour) On entry, the value in X determines the duration in centiseconds of the second named colour. X=0 sets the duration to infinity; X=25 is the default setting.