411 On exit, A is preserved, X and Y contain the value of the previous duration setting, C is undefined. OSBYTE call with A=&B (11) Set keyboard auto-repeat delay On entry, the value in X determines the delay in centiseconds before auto- repeating starts. X=0 disables the auto-repeat facility; X=50 is the default value. On exit, A is preserved, X contains the previous setting, Y and C are undefined. OSBYTE call with A=&C (12) Set keyboard auto-repeat rate On entry, the value in X determines the auto-repeat periodic interval in centiseconds. X=0 resets the auto-repeat delay and rate to their default values; X=8 is the default value.
On exit, A is preserved, X contains the previous setting, Y and C are undefined. OSBYTE call with A=&D (13) Disable events On entry, X contains the event code, corresponding to n for the *FX13, n commands (see later in this chapter). Note that disabling an event means that a user-supplied event handling routine will not be activated should the disabled event occur. The default state is all events disabled. See chapter 44 for more information on events. On exit, A is preserved, X and Y contain the old enable state (0=disabled), C is undefined. OSBYTE call with A=&E (14) Enable events On entry, X contains the event code, corresponding to n for the *FX14 ,n commands (see later in this chapter).
Note that enabling an event means that a user-supplied event handling routine will be activated should the enabled event occur. The default state is all events disabled. See chapter 44 for more information on events. On exit, A is preserved, X and Y contain the old enable state (>0=disabled), C is undefined. OSBYTE call with A=&F (15) Flush selected buffer class On entry, the value in X determines the class of buffer to be flushed, as follows: X=0 All buffers flushed X 0 Input buffer flushed only On exit, the buffer contents are discarded, A is preserved, X, Y and C are undefined.
OSBYTE call with A=&10 (16) Select ADC channels which are to be sampled On entry, X contains the number of channels to be sampled, corresponding to n for the *FX16 ,n commands (see later in this chapter). If n=0, sampling is disabled, if n>4 then n is reset to 4. On exit, A is preserved, X contains the previous setting, Y and C are undefined.