Overview of NC Errors 2.2 Channel Errors NC Errorcodes 10 Version: 1.1 Error(Hex) Error(Dec) Error type Description The channel is not complete, and is therefore not ready for operation. This is usually a consequence of problems at system start-up. 4051 16465♠ Internal Group not ready to operate The group is not complete, and is therefore not ready for operation. This is usually a consequence of problems at system start-up. 4052 16466 Internal Axis not ready to operate The axis is not complete, and is therefore not ready for operation. This is usually a consequence of problems at system start-up. 4060 16480 Internal Channel exists The channel that is to be created already exists.
4061 16481 Internal Group exists The group that is to be created already exists. 4062 16482 Internal Axis exists The axis that is to be created already exists. 4063 16483 Internal Table exists The table that is to be created already exists, resp. it is tried internally to use an already existing table id ( e.g. for the universal flying saw). 4070 16496 Internal Axis index not allowed The location within the channel specified for an axis is not allowed. 4071 16497 Internal Axis index not allowed The location within the group specified for an axis is not allowed.
Error(Hex) Error(Dec) Error type Description 4101 16641 Parameter Group index not allowed The location within the channel specified for a group is not allowed. 4102 16642 Address Null pointer The pointer to the group is invalid. This is usually a consequence of an error at system start-up. 4103 16643 Internal Missing process image It is not possible to exchange data with the PLC. Possible causes: 1. The channel has no interface (no interpreter available). 2. The connection to the PLC is faulty. 4104 16644 Parameter M-function index not allowed Unacceptable M-function (not 0...159) detected at the execution level. 4105 16645 Memory No memory No more system memory is available.
This is usually the result of another error. 4106 16646 Function Not ready