beckhoff TwinCAT 2 Motion — 2.3 Group Errors

Overview of NC Errors NC Errorcodes 23 Version: 1.1 Error(Hex) Error(Dec) Error type Description One of the slave start/coupling parameters is not allowed (Coupling factor is zero, the master position scaling of a cam plate is zero, etc.). 425C 16988 Parameter Slave type is incorrect The slave type does not match up to the (SPP) start type. 425D 16989 Function Axis stop is already active The axis stop/Estop is not initiated, because the stop/estop is already active. 425E 16990 Function Maximum number of tables per slave generator reached The maximum number of tables per slave generator is reached (e.g. "MC MultiCamIn" is limited to 4 tables).

_ 425F 16991 Function The scaling mode is not allowed The used scaling is invalid in this context. Either the mode is not defined or not yet implemented or it cannot be implemented in this constellation. For example, the MASTER-AUTOOFFSET mode cannot be used if relative coupling is performed, since there is a contradiction here. Furthermore, the MASTER-AUTOOFFSET mode cannot be used when coupling for the first time, since no reference to an existing reference table coupling (reference table) can be established here. 4260 16992 Monitoring Controller enable The controller enable for an axis or for a coupled slave axis is not present (see axis interface PlcToNc).

This error occurs if the controller enable is withdrawn while an axis or a group of axes (also a master/slave group) is being actively positioned. The error also occurs if a PTP axis or a coupled slave axis is started without controller enable. 4261 16993 Function Table not found No table exists with the ID prescribed or the table ID is not unique. 4262 16994 Function Incorrect table type The table referred to in the function is of the incorrect type. 4263 16995 Function Single step mode This error occurs if single step mode is selected for a group or axis and a new task is requested while one of the individual tasks is still being processed.

4264 16996 Function Group task unknown (asynchronous table entry) The group has received a task whose type or sub-type is unknown. Valid tasks can be single or multi-dimensional positioning tasks (Geo 1D, Geo 3D), referencing tasks, etc. 4265 16997 Function Group function unknown (synchronous function) The group has received a function whose type is unknown. Valid functions are "Reset", "Stop", "New end position", "Start/stop section compensation", "Set actual position", "Set/reset calibration state" etc. 4266 16998 Function Group task for slave not allowed Group tasks are usually only possible for master axes, not for slave axes.

A slave axis only moves as an indirect result of a positioning task given to its associated master axis. A slave cannot therefore receive an order directly. Exception: see axis parameter "Allow motion commands for slave axes"