beckhoff TwinCAT 2 Motion — 2.3 Group Errors

Overview of NC Errors NC Errorcodes 28 Version: 1.1 Error(Hex) Error(Dec) Error type Description 4290 17040 Monitoring A command with activation position cannot be performed because the axis is already in the brake phase A command with activation position (threshold) e.g. "reach new velocity at position" cannot be performed because the axis is already in the brake phase and the remaining path from the actual position to the activation position is too short.

4291 17041 Monitoring Jerk scaling of the decouple routine when decoupling a slave axis cannot find a valid solution Internal jerk scaling of decouple routine cannot evaluate a valid solution (decoupling slave axis and transform to master axis). Otherwise, an unexpected velocity overshoot, motion reversal or exceeding of the target position could occur. 4292 17042 Monitoring Command cannot be executed because the command buffer is full The command is rejected because the command buffer is full filled. 4293 17043 Internal Command is rejected due to an internal error in the Look Ahead (internal error) The command is rejected due to an internal error in the "look ahead".

4294 17044 Monitoring Command is rejected because the new travel velocity cannot be implemented The command is rejected, because the new travel velocity (target velocity) Vrequ is not realizable and an internal optimizing is impossible. 4295 17045 Monitoring Successive commands have the same end position Successive commands have the same end position. So the travel path is zero.

4296 17046 Monitoring Logical direction of travel of the axis is inconsistent with the parameterized direction of travel of the buffer command In the extended buffer mode, where the actual end position is replaced by the new buffer start position, the logical positioning direction is inconsistent with the direction of the buffer command (=> contradiction). A buffered command (BufferMode, BlendingLow, BlendingPrevious, BlendingNext, BlendingHigh) is rejected with error 0x4296 if the command is using the Beckhoff-specific optional blending position but the blending position is located beyond the target position of the previous motion command.

4297 17047 Monitoring Command is rejected because the remaining distance in the current segment is too short The remaining distance for positioning is not sufficient, therefore the command cannot be executed. This can be the case, for example, in the BufferMode (BlendingMode), if the remaining distance in the current segment is not sufficient to travel without acceleration and to have reached a specified velocity at the segment change (depending on the BufferMode). 429A 17050 Function Restart failed There is already a motion command in the PTP command buffer and another new motion command, which should modify the existing command by a restart, has failed.