Overview of NC Errors NC Errorcodes 29 Version: 1.1 Error(Hex) Error(Dec) Error type Description 429B 17051 Monitoring Group error for invalid start parameters This error refers to a wrong parameterization of the user (group error). E.g. dynamic parameters like Velo, Acc or Dec could be less than or equal to zero. Or the following error cases: - BaseFrequence 200 - BaseAmplitude = 1/(2*CycleTime) 429C 17052 Monitoring PLC referencing cam is not found During the referencing process for an axis it is moved in the direction of the PLC referencing cam. This referencing cam, however, was not found as expected (=> leads to the abortion of the referencing procedure).
429D 17053 Monitoring PLC referencing cam has not been released again During the referencing process for an axis it is moved in the direction of the PLC referencing cam, and is only stopped again when the cam signal is reached. After the axis has also come to a physical standstill, the axis is subsequently started regularly from the cam again. In this case, the reference cam did not become free again as expected when driving down (=> leads to the abortion of the referencing procedure).
429E 17054 Monitoring I/O sync pulse was not found (only when using hardware latch) If the hardware latch is activated, a sync pulse (zero pulse) is expected to be found and a sync event triggered following the expiry of a certain time or a certain distance. If this is not the case, the reaction is an error and the abortion of the referencing procedure. 429F 17055 Function The used buffer mode is unknown or not supported in this context The buffer mode used for a PTP command (e.g. ABORTING, etc.) is unknown or not supported in this context. 42A0 17056 Internal Group/axis consequential error Consequential error resulting from another causative error related to another axis within the group.
Group/axis consequential errors can occur in relation to master/slave couplings or with multiple axis interpolating DXD groups. If, for instance, it is detected that the lag error limit of a master axis has been exceeded, then this consequential error is assigned to all the other master axes and slave axes in this group. 42A1 17057 Parameter Velocity reduction factor for C0/C1 transition is not allowed A C0 transition describes two geometries which, while they are themselves continuous, no not have either continuous first or second differentials. The velocity reduction factor C0 acts on such transitions.
A C1 transition is characterized by the fact that the two geometries have a continuous course, but are continuously differentiable only once. The velocity reduction factor C1 acts on such transitions. Value range: [0.0 ... 1.0] Unit: 1