Overview of NC Errors NC Errorcodes 31 Version: 1.1 Error(Hex) Error(Dec) Error type Description 42B2 17074 Parameter Velocity reduction factor not allowed A parameter that regulates the reduction of velocity at segment transitions is invalid. Parameter: 1. Once continuously differentiable transitions: VeloVertexFactorC1 2. Not continuously differentiable transitions: VeloVertexFactorC0 CriticalVertexAngleLow, CriticalVertexAngleHigh. 42B3 17075 Parameter Helix is a circle The helix has degenerated to a circle, and should be entered as such. 42B4 17076 Parameter Helix is a straight line The helix has degenerated to a straight line, and should be entered as such.
42B5 17077 Parameter Guider parameter not allowed One of the guider's parameters leads to logical errors and/or to an FPU exception. 42B6 17078 Address Invalid segment address (internal error) The geometry segment does not have a valid geometry structure address or does not have a valid dynamic structure address. 42B7 17079 Parameter Not parameterized generator" (internal error) The SPP generator is not yet parameterized and is therefore unable to operate. 42B8 17080 Address Not parameterized table (internal error) The table has no information concerning the address of the corresponding dynamic generator.
42BA 17082 Internal Arc length of the smoothed path (internal error) The calculation of the arc length of the smoothed path. 42BB 17083 Parameter Tolerance sphere The radius of the tolerance sphere is too small (smaller than 0.1 mm). 42BC 17084 Internal DXD software end positions (internal error) An error has occurred in the calculation of the DXD software end positions. 42BD 17085 Function NC block violates software end positions of the group At least one path axis with active software end position monitoring has violated the limit switches. Therefore the geometric entry is denied with an error.
42BE 17086 Parameter A path axis violates the end position At least one path axis with active position limit monitoring violates the limit switches. 42BF 17087 Parameter Invalid reference velocity type 42C0 17088 Internal Interpolating group contains axes of an incorrect axis type An interpolating 3D group may only contain continuously guided axes of axis type 1 (SERVO). 42C1 17089 Internal Scalar product cannot be calculated The length of one of the given vectors is 0.0. 42C2 17090 Internal Inverse cosine cannot be calculated