Overview of NC Errors NC Errorcodes 32 Version: 1.1 Error(Hex) Error(Dec) Error type Description The length of one of the given vectors is 0.0. 42C3 17091 Parameter Invalid table entry type The given table entry type is unknown. 42C4 17092 Parameter Invalid DIN66025 information type (internal error) The given DIN66025 information type is unknown. Known types: G0, G1, G2, G3, G17, G18, G19. 42C5 17093 Parameter Invalid dimension (internal error) The CNC dimension is unknown. Known dimensions: 1, 2, 3. Or: The CNC dimension is invalid for the given geometrical object. For a circle the dimension must be 2 or 3, while for a helix it must be 3.
42C6 17094 Parameter Geometrical object is not a straight line The given object, interpreted as a straight line, has a length of 0.0. 42C7 17095 Parameter Geometrical object is not a circle Interpreted as a circular arc, the given object has a length of 0.0, or an angle of 0.0 or a radius of 0.0. 42C8 17096 Parameter Geometrical object is not a helix Interpreted as a circular arc, the given object has a length of 0.0, or an angle of 0.0, or a radius of 0.0. or a height of 0.0.
42C9 17097 Parameter Target velocity less than or equal to 0.0 is invalid A value less than or equal to 0.0 for the target velocity (CNC) is not allowed, since the target velocity is positive by definition, and a target velocity of 0.0 cannot generate any motion. 42CA 17098 Address Address for look-ahead invalid (internal error) The address supplied for the look-ahead is invalid. 42CB 17099 Function Setpoint generator SEC active Starting the setpoint generator (SEC) has been refused, since the SEC task is already active. 42CC 17100 Function CNC setpoint generation not active The stop or override change was denied because the setpoint generation is not active.
42CD 17101 Function CNC setpoint generation in the stop phase The stop or override change was denied because the setpoint generation is in the stop phase. 42CE 17102 Parameter Override not allowed An override of less than 0.0 % or more than 100.0 % is invalid. 42CF 17103 Address Invalid table address (internal error) The table address given for the initialization of the setpoint generator is invalid, or no valid logger connection (report file) is present. 42D0 17104 Parameter Invalid table entry type The given table entry type is unknown. 42D1 17105 Memory Memory allocation failed The memory allocation for a table failed.
42D2 17106 Memory Memory allocation failed The memory allocation for a filter failed. 42D3 17107 Parameter Invalid parameter