beckhoff TwinCAT 2 Motion — 2.5 Encoder Errors

Overview of NC Errors NC Errorcodes 47 Version: 1.1 Error(Hex) Error(Dec) Error type Description 4415 17429 Parameter External sync pulse (obsolete) The value of the activation or deactivation of the external sync pulse in a referencing procedure is not allowed. Value 0: Passive Value 1: Active Value range: [0, 1] Unit: 1 4416 17430 Parameter Scaling of the noise rate is not allowed The value of the scaling (weighting) of the synthetic noise rate is not allowed. This parameter exists only in the simulation encoder and serves to produce a realistic simulation. Value range: [0, 1000000] Unit:

1 4417 17431 Parameter Tolerance window for modulo-start The value for the tolerance window for the modulo-axis-start is invalid. The value must be greater or equal than zero and smaller than the half encoder modulo-period (e.g. in the interval [0.0,180.0) ). Value range: [0.0, 180.0], Max: 0.5*modulo period Unit: e.g. mm or degrees 4418 17432 Parameter Encoder referencing mode The value for the encoder reference mode is not allowed, resp. is not supported for this encoder type. Value range: [0, 5] Unit: 1 4419 17433 Parameter Encoder evaluation direction The value for the encoder evaluation direction (log. counting direction) is not allowed. Value range: [0, 3] Unit:

1 441A 17434 Parameter Encoder absolute dimensioning system The value for the encoder reference system is invalid: 0: INCREMENTAL, 1: ABSOLUTE, 2: ABSOLUTE+MODULO Value range: [0, 2] Unit: 1 441B 17435 Parameter Encoder position initialization mode When starting the TC system the value for the encoder position initialization mode is invalid. Value range: [0, 1] Unit: 1