Overview of NC Errors NC Errorcodes 48 Version: 1.1 Error(Hex) Error(Dec) Error type Description 441C 17436 Parameter Encoder sign interpretation (UNSIGNED / SIGNED data type) The value for the encoder sign interpretation (data type) for the encoder the actual increment calculation is invalid: 0: default/not defined, 1: UNSIGNED, 2: SIGNED. Value range: [0, 2] Unit: 1 441D 17437 Parameter Homing Sensor Source The value for the Encoder Homing Sensor Source is invalid or not supported for this encoder type. Value range: [0, 16] Unit:
1 4420 17440 Parameter Software end position monitoring minimum not allowed The value for the activation of the software end position monitoring minimum is not allowed. Value range: [0, 1] Unit: 1 4421 17441 Parameter Software end position monitoring maximum not allowed The value for the activation of the software end position monitoring maximum is not allowed. Value range: [0, 1] Unit: 1 4422 17442 Function Actual value setting is outside the value range The "set actual value" function cannot be carried out, because the new actual position is outside the expected range of values. Value range: [-1.0E10, 1.0E10] Unit: e.g.
mm 4423 17443 Parameter Software end position minimum not allowed The value for the software end position minimum is not allowed. Value range: [-1000000000.0, 1000000000.0] Unit: e.g. mm 4424 17444 Parameter Software end position maximum not allowed The value for the software end position maximum is not allowed. Value range: [-1000000000.0, 1000000000.0] Unit: e.g. mm