beckhoff TwinCAT 2 Motion — 2.5 Encoder Errors

Overview of NC Errors NC Errorcodes 50 Version: 1.1 Error(Hex) Error(Dec) Error type Description 4431 17457 Function Activation of external hardware latch / Touch probe function (encoder) The activation of the external hardware latch (only available for KL5101, SERCOS, AX2xxx) is initiated explicitly by an ADS command (called from the PLC program of the Visual Basic interface). If this function has already been activated, but the latch value has not yet been made valid by an external signal ("external latch valid" or "touch probe latched" or "real-time status bit"), another call to the function is refused with this error.

Likewise, it is possible that this function cannot be executed because of another simultaneous function, such as referencing an incremental encoder axis. 4432 17458 Function External hardware latch activation (encoder) If a referencing procedure has previously been initiated and the hardware still signals a valid latch value ("latch valid"), this function must not be called. In practice, however, this error can almost never occur. 4433 17459 Function Activation of external hardware latch / Touch probe function (encoder) This function has been activated before and has not been finished since (the internal handshake communication between NC and I/O device is still active).

In the meantime, a renewed activation is not allowed and is therefore rejected with an error. (If this function has already been triggered before and the hardware still signals that the external latch value is already valid ("external latch valid" or "touch probe" or "real-time status bit"), a renewed activation must not be executed. In this case the validity of the external hardware latch would be signaled immediately by mistake, but still with an old latch value.) 4434 17460 Monitoring Encoder function is not supported An encoder function has been activated that is currently not released for use, or which is not even implemented.

4435 17461 Monitoring Encoder function is already active An encoder function cannot been activated because this functionality is already active.