Overview of NC Errors NC Errorcodes 52 Version: 1.1 Error(Hex) Error(Dec) Error type Description 4463 17507 Monitoring Maximum software position limit (positioning process) While monitoring for the maximum software position limit is active, the actual position has exceeded the maximum software position limit. For servo axes - they are continuously guided - this limit is extended by the amount of the parameterized lag error window. 4464 17508 Monitoring Encoder hardware error The drive resp. the encoder system reports a hardware error of the encoder. An optimal error code is displayed in the message of the event log.

4465 17509 Monitoring Position initialization error at system startup At the first initialization of the actual position was this for all initialization trials (without over-/under-flow, with underflow and overflow) out of the final position minimum and maximum. 4466 17510 Monitoring Invalid I/O data for more than n continuous NC cycles (encoder) The axis (encoder) has detected invalid encoder I/O data for more than n continuous NC cycles (NC SEC task) (e.g. n=3). Typically, an EtherCAT device is a "Working Counter Error" (WcState), which shows that the data transmission between I/O device and controller is disturbed.

If this error is continuously present for a longer period of time, then this can lead to the loss of the referencing of the axis (the "Homed" flag is reset and the encoder gets the state "unreferenced"). Possible reasons for this error: an EtherCAT slave may have left its OP state or there is too high a real-time load on the controller or too high a real- time jitter. 4467 17511 Monitoring Invalid actual position (encoder) The I/O device returns an invalid actual position (for CANopen/CoE see bit 13 of encoder state "TxPDO data invalid" or "invalid actual position value").

4468 17512 Monitoring Invalid I/O input data (error type 1) The monitoring of the "cyclic I/O input counter" (2 bit counter) has detected an error. The input data has not been updated for at least 3 NC SEC cycles (the 2 bit counter shows a constant value for several NC SEC cycles instead of increasing exactly by 1 from cycle to cycle).