Overview of NC Errors 2.6 Controller Errors NC Errorcodes 53 Version: 1.1 Error(Hex) Error(Dec) Error type Description 4469 17513 Monitoring Invalid I/O input data (error type 2) The monitoring of the "cyclic I/O input counter" (2 bit counter) has detected an error. The quality of the input data, based on the 2 bit counter, is not sufficient (there is a simple statistical evaluation here, which evaluates both GOOD cases and bad cases and leads to an error if a special threshold value is exceeded). 4470 17520 Monitoring SSI transformation faulty or not finished The SSI transformation of the FOX 50 module was faulty for some NC-cycles or did not finished respectively.
44A2 17570 Monitoring Internal error ENCERR ADDR CONTROLLER _ _ 44A3 17571 Monitoring Internal error ENCERR INVALID CONTROLLERTY _ _ PE Error(Hex) Error(Dec) Error type Description 4500 17664 Parameter Controller ID not allowed The value for the controller ID is not allowed, e.g. because it has already been assigned, is less than or equal to zero, or is greater than 255. Value range: [1 ... 255] Unit: 1 4501 17665 Parameter Controller type not allowed The value for the controller type is unacceptable because it is not defined. Type 1: P-controller (position) Type 7: Fast/creep controller Type 8: Stepper motor controller Type 9: Sercos controller Value range: [1 ... 9] Unit:
1 4502 17666 Parameter Operation mode controller not allowed The value for the controller operating mode is not allowed. Value range: [1] Unit: 1 4503 17667 Parameter Weighting of the velocity pre-control not allowed The value for the percentage weighting of the velocity pre-control is not allowed. The parameter is pre-set to 1.0 (100%) as standard. Value range: [0.0 ... 1.0] Unit: %