Overview of NC Errors NC Errorcodes 55 Version: 1.1 Error(Hex) Error(Dec) Error type Description 4510 17680 Parameter Proportional gain Kv or Kp (controller) not allowed Position The value for the proportional gain (Kv factor or Kp factor) is not allowed. Value range: [0.0, 10000.0] Unit: e.g. mm/s/mm 4511 17681 Parameter Integral action time Tn (controller) not allowed Position The value for the integral action time is not allowed (I part of the PID T1 controller). Value range: [0.0, 60.0] Unit: s 4512 17682 Parameter Rate time Tv (controller) not allowed Position The value for the derivative action time is not allowed (D part of the PID T1 controller). Value range: [0.0, 60.0] Unit:
s 4513 17683 Parameter Damping time Td (controller) not allowed Position The value for the damping time is not allowed (D part of the PID T1 controller). Value range: [0.0, 60.0] Unit: s 4514 17684 Function Activation of the automatic offset calibration not allowed Activation of the automatic offset calibration is only possible for certain types of controller (with no I component). 4515 17685 Parameter Additional proportional gain Kv or Kp (controller) not allowed Position The value for the second term of the proportional gain (Kv factor or Kp factor) is not allowed. Value range: [0.0, 10000.0] Unit: e.g.
mm/s/mm 4516 17686 Parameter Reference velocity for additional proportional gain Kv or Kp (controller) not allowed Position The value for the reference velocity percentage data entry, to which the additional proportional gain is applied, is not allowed. The standard setting for the parameter is 0.5 (50%). Value range: [0.0 ... 1.0] Unit: %