Overview of NC Errors NC Errorcodes 56 Version: 1.1 Error(Hex) Error(Dec) Error type Description 4517 17687 Parameter Proportional gain Pa (proportion) not allowed Acceleration The value for the proportional gain (Pa factor) is not allowed. Value range: [0.0, 1000000.0] Unit: s 4518 17688 Parameter Proportional gain Kv (controller) not allowed Velocity The value for the proportional gain (Kv factor) is not allowed. Value range: [0.0, 10000.0] Unit: 1 4519 17689 Parameter Integral action time Tn (controller) not allowed Velocity The value for the integral action time is not allowed (I part of the PID T1 controller). Value range: [0.0, 60.0] Unit:
s 451A 17690 Parameter Reserved Reserved, currently not used. 451B 17691 Parameter Reserved Reserved, currently not used. 451C 17692 Parameter Velocity filter time not allowed The parameter for the velocity filter time in seconds is invalid (P-T1 filter). This filter can be used in the NC for filtering an actual velocity or a velocity difference (Geschwindigkeitsfehler = Soll-Geschwindigkeit - Ist- Geschwindigkeit) in special NC controllers (e.g. in the torque interface). Value range: [0.0, 60.0] Unit:
s 451D 17693 Parameter Dead range not allowed The value for the dead range (neutral zone) of the position error or the velocity error (control deviation) is not allowed (applies to more complex controllers with velocity or torque interface). Value range: [0.0, 10000.0] Unit: mm or mm/s 451F 17695 Parameter Proportional gain Kcp not allowed The parameter for the proportional gain Kcp of the slave coupling difference control is invalid. Value range: [0.0, 10000.0] Unit: e.g. mm^2/ mm