beckhoff TwinCAT 2 Motion — 2.6 Controller Errors

Overview of NC Errors NC Errorcodes 58 Version: 1.1 Error(Hex) Error(Dec) Error type Description 4527 17703 Parameter Velocity observer: 'Motor torque constant Kt or Kf' is not allowed The parameter for the motor torque constant Kt (rotary motor) or Kf (linear motor) of the velocity observer of the special NC controller in the torque interface is invalid. Value range: [0.0 .. 100000.0] Unit: Nm/A or N/A 4528 17704 Parameter Velocity observer: 'Motor moment of inertia JM' is not allowed The parameter for the motor moment of inertia J of the velocity observer of the M special NC controller in the torque interface is invalid. Value range: [0.0001 .. 100000.0] Unit:

kg cm^2 4529 17705 Parameter Velocity observer: 'Bandwidth f0' is not allowed The parameter for the bandwidth f of 0 the velocity observer of the special NC controller in the torque interface is invalid. The bandwidth must be less than the reciprocal of 6 times the NC cycle time (f Value range: [0.0 .. 10000.0] Unit: Hz 452A 17706 Parameter Velocity observer: 'Correction factor kc' is not allowed The parameter for the correction factor k of the velocity observer of the special c NC controller in the torque interface is invalid. The correction factor k c establishes the relationship between current and acceleration or angular acceleration. Value range: [0.0 .. 100.0] Unit:

s 452B 17707 Parameter Velocity observer: 'Time constant T for 1st order filter' is not allowed The time constant T for the 1st order velocity filter (PID-T or "Lead Lag") of 2 the velocity observer of the special NC controller in the torque interface is not allowed. The correction factor k c establishes the relationship between current and acceleration or angular acceleration. Value range: [0.0 .. 100.0] Unit: s