beckhoff TwinCAT 2 Motion — 2.7 Drive error

Overview of NC Errors 2.7 Drive error NC Errorcodes 60 Version: 1.1 Error(Hex) Error(Dec) Error type Description 45A3 17827 Monitoring Internal error CONTROLERR RANGE PNENN _ _ 45A4 17828 Monitoring Internal error CONTROLERR RANGE AXISIDPRES _ _ P0 Error(Hex) Error(Dec) Error type Description 4600 17920 Parameter Drive ID not allowed The value for the drive ID is not allowed, e.g. because it has already been assigned, is less than or equal to zero, or is greater than 255. Value range: [1 ... 255] Unit: 1 4601 17921 Parameter Drive type not allowed The value for the drive type is impermissible, since it is not defined. Value range: [1, 20] Unit:

1 4602 17922 Parameter Operation mode drive not allowed The value for the drive operating mode is impermissible (mode 1: standard). Value range: [1] Unit: 1 4603 17923 Parameter Motor polarity inverted? The flag for the motor polarity is invalid. Flag 0: Positive motor polarity Flag 1: Negative motor polarity Value range: [0, 1] Unit: 1 4604 17924 Parameter Drift compensation/velocity offset (DAC offset) The value for the drift compensation (DAC offset) is impermissible. Value range: [-100.0, 100.0] Unit: e.g. m/min 4605 17925 Parameter Reference velocity (velocity pre-control) The value for the reference velocity (also called velocity pre-control) is impermissible. Value range:

[0.0, 10000.0] Unit: e.g. m/min 4606 17926 Parameter Reference output in percent The value for the reference output in percent is impermissible. The value 1.0 (100 %) usually corresponds to a voltage of 10.0 V. Value range: [0.0, 5.0] Unit: % 4607 17927 Parameter Quadrant compensation factor The value for the quadrant compensation factor is impermissible. Value range: [0.0, 100.0] Unit: 1 4608 17928 Parameter Velocity reference point in percent The value for the velocity reference point in percent is impermissible. The value 1.0 corresponds to 100 percent. Value range: [0.01, 1.0] Unit: %