Overview of NC Errors NC Errorcodes 61 Version: 1.1 Error(Hex) Error(Dec) Error type Description 4609 17929 Parameter Output reference point The value for the output reference point in percent is impermissible. The value 1.0 corresponds to 100 percent. Value range: [0.01, 1.0] Unit: % 460A 17930 Parameter Minimum or maximum output limits (output limitation) The value for the minimum and/or maximum output limit is impermissible. This will happen if the value range is exceeded, the maximum limit is smaller than the minimum limit, or the distance between the minimum and maximum limits is zero. The minimum limit is initially set to –1.0 (-100 percent) and the maximum limit to 1.0 (100 percent).
Value range: [-1.0, 1.0] Unit: % 460B 17931 Parameter Parameter 'Maximum value for output' is not allowed The value for the maximum number of output digits of the drive (maximum output value) is not allowed. Depending on the interface used (e.g. position, velocity or torque/current). For a velocity interface this is often a signed 16 bit output value (± 32767). Value range: [0x000000FF .. 0xFFFFFFFF] Unit: INC or Digits 460C 17932 Parameter Parameter 'Internal Drive Control Word' is not allowed The value as internal Drive Control Word for the NC is not allowed. This contains information from the System Manager to the NC, which is evaluated by the NC at the TC start. Value range: [>0] Unit:
1 460D 17933 Parameter Parameter 'Internal timer for RESET behavior Drive' is not allowed The special parameter that influences the internal time behavior between NC Drive and the I/O Drive (servo drive) is not allowed. Value range: [>5] Unit: 1 (NC SEC cycles) 460E 17934 Parameter Parameter 'Master Motion Controller ID' is not allowed The "Master Motion Controller ID" parameter is not allowed for a further NC Motion Controller in slave mode. An additional NC Motion Controller in slave mode can be used if it is one and the same drive device to which different NC information for different operation modes is connected (e.g. velocity mode and torque mode).
This parameter is not directly accessible by the user, but can only be influenced indirectly by configuring additional NC motion controllers underneath the NC axis. Value range: [0 .. 255] Unit: 1 460F 17935 Parameter Drive torque output scaling is not allowed The value is shown as Drive torque output scaling (rotary motor) or as force output scaling (linear motor). Value range: [0, 1000000] Unit: 1 4610 17936 Parameter Drive velocity output scaling is not allowed The value for the drive velocity output scaling is not allowed. Value range: [0, 1000000] Unit: 1