beckhoff TwinCAT 2 Motion — 2.8 Table Errors

Overview of NC Errors NC Errorcodes 67 Version: 1.1 Error(Hex) Error(Dec) Error type Description 4A05 18949 Parameter Period not allowed The value for the period is not allowed, because, for example, it is less than or equal to zero. Value range: [0.001, 1.0E+9] Unit: e.g. mm 4A06 18950 Parameter Table is not monotonic. The value for the step size is not allowed, because, for example, it is less than or equal to zero. 4A07 18951 Initialization Table sub type not allowed The value for the table sub-type is unacceptable because it is not defined. Or the table sub-type and the table class (slave type) do not match. Table sub-types:

(1) equidistant linear position table, (2) equidistant cyclic position table, (3) non-equidistant linear position table, (4) non-equidistant cyclic position table Value range: [1, 4] Unit: 1 4A08 18952 Initialization Table interpolation type not allowed The value for the table interpolation type is invalid because it is not defined. Table interpolation types: (0) linear interpolation, (1) 4-point interpolation, (2) spline interpolation Value range: [0, 2] Unit: 1 4A09 18953 Initialization Incorrect table main type The table main type is not allowed because it is not defined. Or the table main type and the table class (slave type) do not match. Table main types:

(1) cam plate table (camming), (10) characteristic table, (16) 'motion function' table (MF) 4A10 18960 Initialization Table initialization The table has not been initialized. Although the table has been created, the rest of the initialization has not been performed. For instance, the number of lines or columns may be less than or equal to zero. 4A11 18961 Initialization Not enough memory The table could not be created, since there is not enough memory. 4A12 18962 Function Function not executed, function not available The function has not been implemented, or cannot be executed, for the present type of table.

4A13 18963 Function Line index not allowed The start line index or the stop line index to be used for read or write access to the table is not allowed. For instance, the line index is greater than the total number of lines in the table. 4A14 18964 Function Column index not allowed The start column index or the stop column index to be used for read or write access to the table in not allowed. For instance, the column index is greater than the total number of columns in the table. 4A15 18965 Function Number of lines not allowed The number of lines to be read from or written to the table is not allowed.

The number of lines must be an integer multiple of the number of elements in a line (n * number of columns).