beckhoff TwinCAT 2 Motion — 2.8 Table Errors

Overview of NC Errors NC Errorcodes 68 Version: 1.1 Error(Hex) Error(Dec) Error type Description 4A16 18966 Function Number of columns not allowed The number of columns to be read from or written to the table is not allowed. The number of columns must be an integer multiple of the number of elements in a column (n * number of lines). 4A17 18967 Function Error in scaling or in range entry The entries in the table header are inconsistent, e.g. the scope is empty. If the error is generated during the runtime it is a runtime error and stops the master/slave group. 4A18 18968 Function Multi table slave out of range The slave master position is outside the table values for the master.

The error is a runtime error, and stops the master/slave group. 4A19 18969 Function Solo table underflow The slave master position is outside the table values for the master. The master value of the equidistant table, to be processed linearly, lies under the first table value. The error is a runtime error, and stops the master/slave group. 4A1A 18970 Function Solo table overflow The slave master position is outside the table values for the master. The master value of the equidistant table, to be processed linearly, lies above the first table value. The error is a runtime error, and stops the master/slave group.

4A1B 18971 Parameter Incorrect execution mode The cyclic execution mode can only be "TRUE" or "FALSE". 4A1C 18972 Parameter Invalid parameter The Fifo parameter is not allowed. 4A1D 18973 Parameter Fifo is empty The Fifo of the external generator is empty. This can signify an end of track or a runtime error. 4A1E 18974 Parameter Fifo is full The Fifo of the external generator is full. It is the user's task to continue to attempt to fill the Fifo with the rejected values. 4A1F 18975 Parameter Point index of the motion function is invalid. The point index of a Motion Function Point of a Motion Function Table is invalid.

First, the point index must firstly be greater than zero and secondly, it must be numerically consecutive for a column of a Motion Function Table (e.g. 1,2,3,... or 10,11,12,...). Note: The point index must not be changed online, but must be kept constant. 4A20 18976 Initialization No diagonalization of matrix The spline cannot be calculated. The master positions are not correct. 4A21 18977 Initialization Number of spline points too small The number of points of a cubic spline must be at least three. Therefore, the number of lines must be at least three. 4A22 18978 Initialization Fifo must not be overwritten.

The Fifo of the external generator must not be overwritten, otherwise it would be written over the active processing line. It is up to the user to make sure that no changes or deletions are requested across the active line. 4A23 18979 Function Motion Function has too few points