EPSON — Acquisition commands for mode setting values for clogged nozzle check signal (input)

Chapter 3 Commands Acquisition commands for mode setting values for pause signal (input) [Format] ~H(CNI,P [Parameter] None [Function] Acquire the mode setting values for the pause signal. 3 [Format] ~H(CNI,D [Parameter] None [Function] Acquire the mode setting values for the clogged nozzle check signal. 46 Return value after executing this command Description 0 Pause signal (pin 12) ignored 1 Pause signal (pin 12) set to switch to the pause state when a Low signal is input for 30 msec or longer Acquisition commands for mode setting values for head cleaning signal (input) [Format] ~H(CNI,C [Parameter] None [Function] Acquire the mode setting values for the head cleaning signal.

Return value after Description executing this command 0 Head cleaning signal (pin 15) ignored 1 Head cleaning signal (pin 15) set to clean the head when a Low signal is input for 30 msec or longer Acquisition commands for mode setting values for clogged nozzle check signal (input) Return value after executing this command Description 0 Head cleaning signal (pin 15) ignored 1 Head cleaning signal (pin 15) set to clean the head when a Low signal is input for 30 msec or longer Return value after executing this command Description 0 Clogged nozzle check signal (pin 14) ignored 1 Clogged nozzle check signal (pin 14) set to check the nozzles when a Low signal is input for 30 msec or longer.